Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Interv Cardiol ; 2022: 7245384, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36189196

RESUMO

Background: If surgical revascularization is not feasible, high-risk PCI is a viable option for patients with complex coronary artery disease. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) provides hemodynamic support in patients with a high risk for periprocedural cardiogenic shock. Objective: This study aims to provide data about short-term outcomes of elective high-risk PCI with ECMO support. Methods: A retrospective single-center registry was performed on patients with high-risk PCI receiving VA-ECMO support. The short-term outcome was defined as the incidence of major adverse cardiac events (MACE) during the hospital stay and within 60 days after discharge. Results: Between January 2020 and December 2021, 14 patients underwent high-risk PCI with ECMO support. The mean age was 66.5 (±2.5) and the majority was male (71.4%) with a mean left ventricular ejection fraction of 33% (±3.0). Complexity indexes were high (STS-PROM risk score: 2.9 (IQR 1.5-5.8), SYNTAX score I: 35.5 (±2.0), SYNTAX score II (PCI): 49.8 (±3.2)). Femoral artery ECMO cannulation was performed in 13 patients (92.9%) requiring additional antegrade femoral artery cannula in one patient because of periprocedural limb ischemia. The mean duration of the ECMO run was 151 (±32) minutes. One patient required prolonged ECMO support and was weaned after 2 days. Successful revascularization was achieved in 13 patients (92.8%). Procedural success was achieved in 12 patients (85.7%) due to one unsuccessful revascularization and one procedural death. MACE during hospital stay occurred in 4 patients (28.6%) and within 60 days after discharge in 2 patients (16.7%). Conclusion: High-risk PCI with hemodynamic support using VA-ECMO is a feasible treatment option, if surgical revascularization is considered very high risk. Larger and prospective studies are awaited to confirm the benefits of ECMO support in elective high-risk PCI comparing ECMO with other mechanical circulatory support devices, including coaxial left cardiac support devices and IABP. Trial Registration. This trial is registered with NCT05387902.


Assuntos
Oxigenação por Membrana Extracorpórea , Intervenção Coronária Percutânea , Idoso , Feminino , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Estudos Retrospectivos , Choque Cardiogênico/cirurgia , Volume Sistólico , Função Ventricular Esquerda
2.
Ann Thorac Surg ; 110(6): 2062-2069, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32525029

RESUMO

BACKGROUND: The aim of this study was to evaluate early and mid-term outcomes (mortality and prosthetic valve reintervention) after mitral valve replacement with 15- to 17-mm mechanical prostheses. METHODS: A multicenter, retrospective cohort study was performed among patients who underwent mitral valve replacement with a 15- to 17-mm mechanical prosthesis at 6 congenital cardiac centers: 5 in The Netherlands and 1 in the United States. Baseline, operative, and follow-up data were evaluated. RESULTS: Mitral valve replacement was performed in 61 infants (15 mm, n = 17 [28%]; 16 mm, n = 18 [29%]; 17 mm, n = 26 [43%]), of whom 27 (47%) were admitted to the intensive care unit before surgery and 22 (39%) required ventilator support. Median age at surgery was 5.9 months (interquartile range [IQR] 3.2-17.4), and median weight was 5.7 kg (IQR, 4.5-8.8). There were 13 in-hospital deaths (21%) and 8 late deaths (17%, among 48 hospital survivors). Major adverse events occurred in 34 (56%). Median follow-up was 4.0 years (IQR, 0.4-12.5) First prosthetic valve replacement (n = 27 [44%]) occurred at a median of 3.7 years (IQR, 1.9-6.8). Prosthetic valve endocarditis was not reported, and there was no mortality related to prosthesis replacement. Other reinterventions included permanent pacemaker implantation (n = 9 [15%]), subaortic stenosis resection (n = 4 [7%]), aortic valve repair (n = 3 [5%], and aortic valve replacement (n = 6 [10%]). CONCLUSIONS: Mitral valve replacement with 15- to 17-mm mechanical prostheses is an important alternative to save critically ill neonates and infants in whom the mitral valve cannot be repaired. Prosthesis replacement for outgrowth can be carried out with low risk.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Feminino , Doenças das Valvas Cardíacas/etiologia , Doenças das Valvas Cardíacas/mortalidade , Humanos , Lactente , Masculino , Países Baixos , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos
3.
Ann Thorac Surg ; 110(3): 956-961, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31962116

RESUMO

BACKGROUND: The aim of this study was to evaluate early and long-term outcomes (mortality and prosthetic valve replacement) after mitral valve replacement with the 15-mm St Jude Medical prosthesis (St Jude Medical, St Paul, MN). METHODS: A multicenter, retrospective cohort study was performed among patients who underwent mitral valve replacement with a 15-mm St Jude Medical Masters prosthesis at 4 congenital cardiac centers in The Netherlands. Operative results were evaluated and echocardiographic data studied at 0.5, 1, 2, 3, 5, and 10 years after surgery. RESULTS: Surgery was performed in 17 infants. Ten patients (59%) were treated in the intensive care unit before surgery; 8 (47%) were on ventilator support. Median age at surgery was 3.2 months (interquartile range [IQR], 1.2-5.6), and median weight was 5.2 kg (IQR 3.9-5.7). There was 1 early cardiac death and 1 late noncardiac death. Median follow-up time was 9.6 years (IQR, 2.4-13.2), including 8 patients with a follow-up more than 10 years. The first prosthetic valve explantation (n = 11) occurred at a median of 2.9 years (IQR, 2.0-5.4). Other reinterventions were permanent pacemaker implantation (n = 3), subaortic stenosis resection (n = 2), and paravalvular leak repair (n = 1). Prosthetic valve gradients increased from a mean of 5.0 mm Hg (at discharge) to a mean of 14.3 mm Hg (at 5-year follow-up). CONCLUSIONS: Mitral valve replacement with the 15-mm prosthesis can safely be performed in infants and even in neonates. Median freedom from prosthesis replacement for outgrowth is 3.5 years. Thromboembolic complications were rare.


Assuntos
Previsões , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Pré-Escolar , Ecocardiografia , Feminino , Seguimentos , Humanos , Lactente , Masculino , Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
4.
Ned Tijdschr Geneeskd ; 160: D217, 2015.
Artigo em Holandês | MEDLINE | ID: mdl-27007936

RESUMO

In the 1960s, the Starr-Edwards valve was the first artificial heart valve to be successfully implanted in humans. This valve has now been in use for decades with outstanding results: patients whose life expectancy had previously been short acquired a good prognosis with this development. Nowadays the Starr-Edwards valve is not used anymore, but patients are being described today in whom these valves are still functioning well after more than 40 years.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Valva Mitral , Implante de Prótese de Valva Cardíaca , Humanos , Expectativa de Vida , Prognóstico
5.
Ann Thorac Surg ; 83(5): 1873-4, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17462420

RESUMO

We describe the successful use of cardiac resynchronization therapy for treatment of mitral valve systolic anterior motion with left ventricle outflow tract obstruction after re-excision of a subaortic membrane and septal myectomy in a 12-year-old child. In the recovery phase, a total atrioventricular block persisted. Therefore a permanent atrioventricular pacing system was implanted.


Assuntos
Estenose Aórtica Subvalvar/cirurgia , Estimulação Cardíaca Artificial , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Bloqueio Cardíaco/terapia , Doenças das Valvas Cardíacas/terapia , Criança , Feminino , Bloqueio Cardíaco/etiologia , Doenças das Valvas Cardíacas/etiologia , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/cirurgia , Valva Mitral , Recidiva , Reoperação , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...